Skip to content

Free guides, courses & tools across 12 engineering disciplines

Structures & construction

Stair Calculator

Number of risers, riser height, going, total run and comfort check for a stair.

ArchitectureCivil

Loading calculator…

Lay out a straight stair from the floor-to-floor height: how many risers, how tall each one is, and whether the stair is comfortable and within common code limits.

How to use this calculator

  1. Enter the total rise (finished floor to finished floor).
  2. Enter the largest riser you will accept and the going (tread depth).
  3. Read the layout and the checks.

Formula

n = ceil(H / Rmax), R = H / n, comfort: 2R + G ≈ 600–650 mm (Blondel)

Checks shown: IBC residential (riser ≤ 196 mm, tread ≥ 254 mm) and UK Approved Document K private stairs (rise 150–220 mm, going 220–300 mm, pitch ≤ 42°). Always confirm with your local code.

Worked example

H = 2800 mm, max riser 180 mm, going 270 mm: 16 risers of 175 mm, 15 treads, run 4.05 m, pitch 33°, 2R + G = 620 mm.

Frequently asked questions

What is the going?

The horizontal depth of one tread, measured nosing to nosing — not counting the overhang.

Why is there one tread fewer than risers?

The top floor itself is the last step, so a stair has n risers and n − 1 treads.

Results are for learning and preliminary design. Check critical work against the relevant codes and a qualified engineer.