Lay out a straight stair from the floor-to-floor height: how many risers, how tall each one is, and whether the stair is comfortable and within common code limits.
How to use this calculator
- Enter the total rise (finished floor to finished floor).
- Enter the largest riser you will accept and the going (tread depth).
- Read the layout and the checks.
Formula
n = ceil(H / Rmax), R = H / n, comfort: 2R + G ≈ 600–650 mm (Blondel)Checks shown: IBC residential (riser ≤ 196 mm, tread ≥ 254 mm) and UK Approved Document K private stairs (rise 150–220 mm, going 220–300 mm, pitch ≤ 42°). Always confirm with your local code.
Worked example
H = 2800 mm, max riser 180 mm, going 270 mm: 16 risers of 175 mm, 15 treads, run 4.05 m, pitch 33°, 2R + G = 620 mm.
Frequently asked questions
What is the going?
The horizontal depth of one tread, measured nosing to nosing — not counting the overhang.
Why is there one tread fewer than risers?
The top floor itself is the last step, so a stair has n risers and n − 1 treads.
Results are for learning and preliminary design. Check critical work against the relevant codes and a qualified engineer.